Curtain wall
♦ A curtain wall system is an outer covering of a building in which the outer walls are non-structural, utilized only to keep the weather out and the occupants in.
Since the curtain wall is non -structural, it can be made of lightweight materials, thereby reducing construction costs. When glass is used as the curtain wall, an advantage is that natural light can penetrate deeper within the building. The curtain wall façade does not carry any structural load from the building other than its own dead load weight. The wall transfers lateral wind loads that are incident upon it to the main building structure through connections at floors or columns of the building. A curtain wall is designed to resist air and water infiltration, absorb sway induced by wind and seismic forces acting on the building, withstand wind loads, and support its own weight.
♦ Curtain walls can be classified by their method of fabrication and installation into the following general categories: stick systems and unitized (also known as modular) systems.
a): In the stick system, the curtain wall frame (mullions) and glass or opaque panels are installed and connected together piece by piece.
b): In the unitized system, the curtain wall is composed of large units that are assembled and glazed in the factory, shipped to the site and erected on the building.
Vertical and horizontal mullions of the modules mate together with the adjoining modules. Modules are generally constructed one story tall and one module wide but may incorporate multiple modules. Typical units are five to six feet wide.
Stick System Unitized System
Performance
1.Deflection Test:Serviceability design wind pressure(3000 Pa)
Rating: N6 (General)
2.Air infiltration test - Test method AS4420.4-1996:
+75 Pa: 0.63 L/s·m 2 ;
-75 Pa: 0.80 L/s·m 2 ;
Average air leakage rate: 0.7 L/s·m 2
3.Water resistance test - Test method AS4420.5-1996:
Test Pressure: 900Pa
4.Ultimate strength test - Test method AS4420.6-1996:
Test Pressure: 4500 Pa
Rating: N6 (General)